ASAP Semiconductor

Fill the RFQ Form for AF09-22-00-11 Part Under Control Automation of Abb Low Voltage

You have arrived on the RFQ page for AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces.). AF. contactors include an electronic coil interface accepting a wide control voltage Uc min. . Uc max. Only four coils cover control voltages between 24.500 V 50/60 Hz or 20.500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF. series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: - AF.-.-.-11 not suitable for a direct control by PLC-output. - AF.-.-.-11 type available in some countries: please consult your ABB representative. part number AF09-22-00-11 by Abb Low Voltage, a leading manufacturer featured on our Approved Vendor List (AVL). The particular part you have taken an interest in is featured in our catalog of Contactors & Starters components and may be purchased at any time. To begin the procurement process, all you need to do is complete and submit the form on this page, making sure to include information about your operational needs and restrictions. With knowledge of details like your expected delivery date and target budget, a dedicated account manager will craft a custom quote that has been tailored to your requirements within 15 minutes of receiving your submission.

Part number AF09-22-00-11 is just one of the many AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces.). AF. contactors include an electronic coil interface accepting a wide control voltage Uc min. . Uc max. Only four coils cover control voltages between 24.500 V 50/60 Hz or 20.500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF. series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: - AF.-.-.-11 not suitable for a direct control by PLC-output. - AF.-.-.-11 type available in some countries: please consult your ABB representative. items that we have available within the Control Automation section of our database. At Industrial Parts Dispatch, we prioritize connecting our customers with the highest quality components at competitive prices, and as such, we go to great lengths to guarantee the caliber of our offerings. For example, part number AF09-22-00-11 and every other product in our inventory is sourced from leading manufacturers on our Approved Vendor List (AVL), such as Abb Low Voltage. We even subject components to rigorous quality assurance measures to ensure their proper fit, form, and function prior to your purchase. Get started today to see how we can serve as your industrial automation part procurement partner!

Part NumberAF09-22-00-11
DescriptionAF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces.). AF. contactors include an electronic coil interface accepting a wide control voltage Uc min. . Uc max. Only four coils cover control voltages between 24.500 V 50/60 Hz or 20.500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF. series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: - AF.-.-.-11 not suitable for a direct control by PLC-output. - AF.-.-.-11 type available in some countries: please consult your ABB representative.
ManufacturerAbb Low Voltage

Description

AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces.). AF. contactors include an electronic coil interface accepting a wide control voltage Uc min. . Uc max. Only four coils cover control voltages between 24.500 V 50/60 Hz or 20.500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF. series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: - AF.-.-.-11 not suitable for a direct control by PLC-output. - AF.-.-.-11 type available in some countries: please consult your ABB representative.

Request a Quote

1
2
3

Part Information

If You Have Multiple Parts Requirement, You Can Upload Your Parts List or BOM Here!